functionkc_laminar_KC
Mean heat transfer coefficient of straight pipe | uniform wall temperature or uniform heat flux | hydrodynamically developed or undeveloped laminar flow regime
Extends from Modelica.Icons.Function (Icon for functions).
Information
Calculation of mean convective heat transfer coefficient kc of a straight pipe at an uniform wall temperature or uniform heat flux and for a hydrodynamically developed or undeveloped laminar fluid flow. See more information .
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Fluid.Dissipation.HeatTransfer.StraightPipe.kc_laminar_IN_con | IN_con | Input record for function kc_laminar_KC | |
| Modelica.Fluid.Dissipation.HeatTransfer.StraightPipe.kc_laminar_IN_var | IN_var | Input record for function kc_laminar_KC |
Outputs
| Type | Name | Default | Description |
|---|---|---|---|
| SI.CoefficientOfHeatTransfer | kc | Output for function kc_laminar_KC |
Contents
| Name | Description |
|---|---|
| TYPprotected |
Revisions
2014-08-05 Stefan Wischhusen: Corrected term for Uniform heat flux in developed fluid flow (Nu3).
2016-04-11 Stefan Wischhusen: Removed singularity for Re at zero mass flow rate.