functiondp_suddenChange_DP

Pressure loss of orifice with sudden change in cross sectional area | calculate pressure loss | turbulent flow regime | smooth surface | arbitrary cross sectional area | without baffles | sharp edge

Extends from Modelica.Icons.Function (Icon for functions).

Information

Calculation of the local pressure loss at a sudden change of the cross sectional areas (sudden expansion or sudden contraction) with sharp corners at turbulent flow regime for incompressible and single-phase fluid flow through arbitrary shaped cross sectional area (square, circular, etc.) considering a smooth surface. The flow direction determines the type of the transition. In case of the design flow a sudden expansion will be considered. At flow reversal a sudden contraction will be considered.

Generally this function is numerically best used for the incompressible case, where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. On the other hand the function dp_suddenChange_MFLOW is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. See more information.

Inputs

TypeNameDefaultDescription
Modelica.Fluid.Dissipation.PressureLoss.Orifice.dp_suddenChange_IN_conIN_conInput record for function dp_suddenChange_DP
Modelica.Fluid.Dissipation.PressureLoss.Orifice.dp_suddenChange_IN_varIN_varInput record for function dp_suddenChange_DP
SI.MassFlowRatem_flowMass flow rate

Outputs

TypeNameDefaultDescription
SI.PressureDPOutput for function dp_suddenChange_DP