recorddp_suddenChange_IN_con

Input record for function dp_suddenChange_DP and dp_suddenChange_MFLOW

Extends from Modelica.Fluid.Dissipation.Utilities.Records.PressureLoss.SuddenChange (Input for sudden change of diameter).

Information

This record is used as input record for the pressure loss functions dp_suddenChange_DP and dp_suddenChange_MFLOW.

Components

TypeNameDefaultDescription
SI.AreaA_1 (from SuddenChange)PI*0.01^2/4Small cross sectional area of orifice
SI.AreaA_2 (from SuddenChange)A_1Large cross sectional area of orifice
SI.LengthC_1 (from SuddenChange)PI*0.01Small perimeter of orifice
SI.LengthC_2 (from SuddenChange)C_1Large perimeter of orifice