modelSMR_Inverter
Starting of synchronous reluctance machine with inverter
Extends from Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMR_Inverter (Starting of synchronous reluctance machine with inverter).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | m (from SMR_Inverter) | 3 | Number of stator phases |
| SI.Voltage | VsNominal (from SMR_Inverter) | 100 | Nominal RMS voltage per phase |
| SI.Frequency | fsNominal (from SMR_Inverter) | smrData.fsNominal | Nominal frequency |
| SI.Frequency | fKnee (from SMR_Inverter) | 50 | Knee frequency of V/f curve |
| SI.Time | tRamp (from SMR_Inverter) | 1 | Frequency ramp |
| SI.Torque | T_Load (from SMR_Inverter) | 46 | Nominal load torque |
| SI.Time | tStep (from SMR_Inverter) | 1.2 | Time of load torque step |
| SI.Inertia | J_Load (from SMR_Inverter) | 0.29 | Load inertia |
| Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_ReluctanceRotorData | smrData (from SMR_Inverter) | Synchronous machine data |