modelIMC_Initialize
Steady-state initialization of induction machine with squirrel cage
Extends from Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_Initialize (Steady-state initialization of induction machine with squirrel cage).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | m (from IMC_Initialize) | 3 | Number of phases |
| SI.Voltage | VNominal (from IMC_Initialize) | 100 | Nominal RMS voltage per phase |
| SI.Frequency | fNominal (from IMC_Initialize) | imc.fsNominal | Nominal frequency |
| SI.AngularVelocity | wSync (from IMC_Initialize) | 2*pi*fNominal/imcData.p | Synchronous speed |
| SI.Time | tStart (from IMC_Initialize) | 0.5 | Start time |
| SI.Torque | TLoad (from IMC_Initialize) | 161.4 | Nominal load torque |
| SI.AngularVelocity | wLoad (from IMC_Initialize) | 1440.45*2*Modelica.Constants.pi/60 | Nominal load speed |
| SI.Inertia | JLoad (from IMC_Initialize) | 0.29 | Load's moment of inertia |
| Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SquirrelCageData | imcData (from IMC_Initialize) | Induction machine data |