blockSampleVectorizedAndClocked

Sample the continuous-time, Real input signal vector and provide it as clocked output signal vector. The clock is provided as input signal

Extends from Modelica_Synchronous.RealSignals.Interfaces.SamplerIcon (Basic graphical layout of block used for sampling of Real signals).

Information

This block is similar to the SampleClocked block. The only difference is that the continuous-time input signal is a vector: All input signals are sampled and are associated with the scalar clock signal provided via the second input.

Example

The following example has a vector as input, consisting of two different sine signals. These signals are sampled with a periodic clock of 20 ms period:

   
model simulation result

Parameters

TypeNameDefaultDescription
Integern1Size of input signal vector u (= size of output signal vector y)

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInput[n]uConnector of continuous-time, Real input signal vector
Modelica.Blocks.Interfaces.RealOutput[n]yConnector of clocked, Real output signal vector
Modelica_Synchronous.ClockSignals.Interfaces.ClockInputclockOutput signal vector y is associated with this clock input