.Modelica_Synchronous.RealSignals.Sampler.Utilities.AssignClockToTriggerHold

Information

This block creates a Boolean, continuous time, trigger signal whenever the clock of the input signal is active.

A particular use-case in which that block might be useful is the combination of "old-style" sampled blocks (i.e., "unclocked" discrete control functions implemented using equations between "when trigger then" clauses) with clocked blocks.

Example

The following example samples a sine signal with a periodic clock of 20 ms period. After that a continuous time Boolean trigger signal is generated at every clock tick of that sampled signal. The generated signal is used as trigger signal for an "old-style" TriggeredSampler block from the Modelica.Blocks.Discrete package:

   
model simulation result

Note, that it is clearly visible in the plot that the "old-style" discrete variables have an implicit zero-order hold semantics, while the new clocked variables are only active whenever their associated clock ticks. Just compare variable sample.y (clocked) with triggeredSampler.y (unclocked) to observe the difference.


Generated at 2024-12-22T19:25:51Z by OpenModelicaOpenModelica 1.24.3 using GenerateDoc.mos