modelZIP

ZIP Load

Extends from BaseClasses.baseLoad (Base load for PSAT models).

Parameters

TypeNameDefaultDescription
Types.ApparentPowerSn (from baseLoad)S_bPower rating
Types.PerUnitPz0.33Conductance
Types.PerUnitPi0.33Active current
Types.PerUnitPp1 - Pz - PiActive power
Types.PerUnitQz0.33Susceptance
Types.PerUnitQi0.33Reactive current
Types.PerUnitQp1 - Qz - QiReactive power
Power flow data
Types.ApparentPowerS_b (from pfComponent)SysData.S_bSystem base power
Types.VoltageV_b (from pfComponent)400e3Base voltage of the bus
Types.Frequencyfn (from pfComponent)SysData.fnSystem frequency
Types.ActivePowerP_0 (from pfComponent)1e6Initial active power
Types.ReactivePowerQ_0 (from pfComponent)0Initial reactive power
Types.PerUnitv_0 (from pfComponent)1Initial voltage magnitude
Types.Angleangle_0 (from pfComponent)0Initial voltage angle
BooleandisplayPF (from pfComponent)falseDisplay power flow:
Parameter mask
BooleanenableS_b (from pfComponent)falseEnable S_b in parameter list
BooleanenableV_b (from pfComponent)falseEnable V_b in parameter list
Booleanenablefn (from pfComponent)falseEnable fn in parameter list
BooleanenableP_0 (from pfComponent)falseEnable P_0 in parameter list
BooleanenableQ_0 (from pfComponent)falseEnable Q_0 in parameter list
Booleanenablev_0 (from pfComponent)falseEnable v_0 in parameter list
Booleanenableangle_0 (from pfComponent)falseEnable angle_0 in parameter list
BooleanenabledisplayPF (from pfComponent)falseEnable displayPF in parameter list

Connectors

TypeNameDefaultDescription
Interfaces.PwPinp (from baseLoad)

Components

TypeNameDefaultDescription
OpenIPSL.Electrical.SystemBaseSysData (from pfComponent)Must add this line in all models
Types.PerUnitv (from baseLoad)Voltage magnitude
Types.Angleanglev (from baseLoad)Voltage angle
Types.PerUnitP (from baseLoad)Active power
Types.PerUnitQ (from baseLoad)Reactive power

Revisions

Reference

PSAT Manual 2.1.8

Last update

2015-09

Author

Joan Russinol, KTH Royal Institute of Technology

Contact

see UsersGuide.Contact