modelMotorTypeV

Induction Machine - Order V

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

TypeNameDefaultDescription
Power flow data
Types.ApparentPowerS_b (from pfComponent)SysData.S_bSystem base power
Types.VoltageV_b (from pfComponent)400e3Base voltage of the bus
Types.Frequencyfn (from pfComponent)SysData.fnSystem frequency
Types.ActivePowerP_0 (from pfComponent)1e6Initial active power
Types.ReactivePowerQ_0 (from pfComponent)0Initial reactive power
Types.PerUnitv_0 (from pfComponent)1Initial voltage magnitude
Types.Angleangle_0 (from pfComponent)0Initial voltage angle
BooleandisplayPF (from pfComponent)falseDisplay power flow:
Parameter mask
BooleanenableS_b (from pfComponent)falseEnable S_b in parameter list
BooleanenableV_b (from pfComponent)falseEnable V_b in parameter list
Booleanenablefn (from pfComponent)falseEnable fn in parameter list
BooleanenableP_0 (from pfComponent)falseEnable P_0 in parameter list
BooleanenableQ_0 (from pfComponent)falseEnable Q_0 in parameter list
Booleanenablev_0 (from pfComponent)falseEnable v_0 in parameter list
Booleanenableangle_0 (from pfComponent)falseEnable angle_0 in parameter list
BooleanenabledisplayPF (from pfComponent)falseEnable displayPF in parameter list
Machine parameters
IntegerSup1Start up control
Types.PerUnitRs0.01Stator resistance
Types.PerUnitXs0.15Stator reactance
Types.PerUnitRr10.051st cage rotor resistance
Types.PerUnitXr10.151st cage rotor reactance
Types.PerUnitRr20.0012nd cage rotor resistance
Types.PerUnitXr20.042nd cage rotor reactance
Types.PerUnitXm5Magnetizing reactance
Types.TimeHm3Inertia constant
Types.PerUnita0.131st coefficient of tau_m(w)
Types.PerUnitb0.022nd coefficient of tau_m(w)
Types.PerUnitc0.0243rd coefficient of tau_m(w)
Types.Timetup0Start up time

Connectors

TypeNameDefaultDescription
OpenIPSL.Interfaces.PwPinp

Components

TypeNameDefaultDescription
OpenIPSL.Electrical.SystemBaseSysData (from pfComponent)Must add this line in all models
Types.PerUnitvBus voltage magnitude
Types.Angleanglev Bus voltage angle
Types.PerUnits
Types.PerUnitTm
Types.PerUnitTe
Types.PerUnitP
Types.PerUnitQ
Types.PerUnite1r
Types.PerUnite1m
Types.PerUnite2r
Types.PerUnite2m
Types.PerUnitVr
Types.PerUnitVm
Types.PerUnitIr
Types.PerUnitIm

Revisions

Reference

PSAT Manual 2.1.8

Last update

September 2015

Author

Joan Russinol, KTH Royal Institute of Technology

Contact