modelPQ1
Constant PQ Generator, Solar Photo-Voltaic Generator
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ApparentPower | Sn | SysData.S_b | Nominal power |
| Types.Time | Td | 15 | d-axis inverter time constant |
| Types.Time | Tq | 15 | q-axis inverter time constant |
| Power flow data | |||
| Types.ApparentPower | S_b | SysData.S_b | System base power |
| Types.PerUnit | v_0 | 1.00018548610126 | Voltage magnitude |
| Types.Angle | angle_0 | -0.0000253046024029618 | Voltage angle |
| Types.PerUnit | P_0 | 0.4 | Active power |
| Types.PerUnit | Q_0 | 0.3 | Reactive power |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| OpenIPSL.Interfaces.PwPin | p |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| OpenIPSL.Electrical.SystemBase | SysData | Use outer SystemBase record | |
| Types.PerUnit | v | Bus voltage magnitude | |
| Types.Angle | anglev | Bus voltage angle | |
| Types.PerUnit | id | d-axis current | |
| Types.PerUnit | iq | q-axis current | |
| Types.PerUnit | vd | d-axis voltage | |
| Types.PerUnit | vq | q-axis voltage | |
| Types.PerUnit | P | Active power | |
| Types.PerUnit | Q | Reactive power | |
| Types.PerUnit | idref1 | d-axis current setpoint | |
| Types.PerUnit | iqref1 | q-axis current setpoint |
Revisions
Reference |
PSAT Manual 2.1.8 |
Last update |
2015-09 |
Author |
Joan Russinol, KTH Royal Institute of Technology |
Contact |