modelPVModule

Model of a single PV module

Information

Model of a PV Module within a PV array.

Parameters

TypeNameDefaultDescription
SI.VoltageU0_stc43.8Open-circuit voltage at Standard Test Conditions
SI.VoltageUmpp_stc35MPP voltage at Standard Test Conditions
Types.CurrentImpp_stc4.58MPP current at Standard Test Conditions
Types.CurrentIsc_stc5Short-circuit current at Standard Test Conditions
SI.LinearTemperatureCoefficientau-0.0039Temperature correction factor (voltage)
SI.LinearTemperatureCoefficientai0.0004Temperature correction factor (current)
Booleanuse_input_EfalseIf true irradiance is used as input
Booleanuse_input_thetafalseIf true temperature is used as input
Types.ActivePowerP_initInitial active power (needed only if input E is not used)
SI.IrradianceE_STC1000
SI.Temperaturetheta_STC298.15

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputU
Modelica.Blocks.Interfaces.RealInputE
Modelica.Blocks.Interfaces.RealInputtheta
Modelica.Blocks.Interfaces.RealOutputI
Modelica.Blocks.Interfaces.RealOutputUmpp

Components

TypeNameDefaultDescription
Types.VoltageU0Open-circuit voltage
Types.CurrentIscShort-circuit current
Types.CurrentImppMPP Current
RealtempCorrUVoltage Correction Factor
RealtempCorrICurrent Correction Factor
Modelica.Blocks.Sources.RealExpressionnot_use_input_theta
Modelica.Blocks.Sources.RealExpressionnot_use_input_E

Revisions

Model Name

PV Module

Reference

PowerFactory Implementation in Templates

Last update

January 2021

Author

@tinrabuzin

Contact

see UsersGuide.Contact

Model Verification

This model has not been verified against PowerFactory.