modelReactivePowerControl
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.Time | Tfv | 0.15000 | Filter time constant in voltage regulator |
| Types.PerUnit | Kpv | 18.000 | Proportional gain in voltage regulator |
| Types.TimeAging | KIV | 5.0000 | Integrator gain in voltage regulator |
| Types.PerUnit | Xc | 0.0000 | Line drop compensation reactance |
| Types.PerUnit | QMX | 0.29600 | Max limit in voltage regulator |
| Types.PerUnit | QMN | -0.43600 | Min limit in voltage regulator |
| Types.Time | TRV | 0.50000E-01 | Voltage sensor time constant |
| Types.Time | Tv | 0.50000E-01 | Lag time constant in WindVar controller |
| Real | Fn | 1.0000 | A portion of online wind turbines |
| Types.PerUnit | Vref | Remote bus ref voltage | |
| Types.PerUnit | k0 | ||
| Types.PerUnit | k10 | ||
| Types.PerUnit | k40 | ||
| Types.PerUnit | k80 |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | ITERM | ||
| Modelica.Blocks.Interfaces.RealInput | VTERM | ||
| Modelica.Blocks.Interfaces.RealOutput | Q_ord |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| NonElectrical.Continuous.SimpleLag | K4 | ||
| NonElectrical.Continuous.SimpleLag | K8 | ||
| NonElectrical.Continuous.SimpleLag | K | ||
| Modelica.Blocks.Math.Gain | XC | Line drop compensation reactance | |
| Modelica.Blocks.Math.Add | add3 | ||
| Modelica.Blocks.Sources.Constant | VARL | ||
| Modelica.Blocks.Math.Gain | portion | ||
| NonElectrical.Continuous.SimpleLag | K1 | ||
| Modelica.Blocks.Math.Add | add4 | ||
| Modelica.Blocks.Math.Add | add5 | ||
| Modelica.Blocks.Nonlinear.Limiter | Qord1 | ||
| NonElectrical.Continuous.SimpleLag | K10 |