blockSimpleLagRateLimBlock

First order lag transfer function block with a non windup limiter, rate limits and blocking input

Extends from Modelica.Blocks.Interfaces.SISO (Single Input Single Output continuous control block).

Parameters

TypeNameDefaultDescription
RealKGain
Types.TimeTLag time constant
RealoutMaxMaximum output value
RealoutMinMinimum output value
RealrminMinimum rate limit
RealrmaxMaximum rate limit
Initialization
Realy_startOutput start value

Connectors

TypeNameDefaultDescription
RealInputu (from SISO)Connector of Real input signal
RealOutputy (from SISO)Connector of Real output signal
Modelica.Blocks.Interfaces.RealInputBlock

Components

TypeNameDefaultDescription
Realx
Realrate

Revisions

Reference

IEEE Std. 421.5-2005, Annex E

Last update

2015-11-25

Author

@tinrabuzin

Contact

see UsersGuide.Contact