modelTicagrelor_strand2019_PD_pru

sigmoid_emax exposure-response sweep — Åstrand_2019 :: PRU (P2Y12 reaction units (PRU))

Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).

Information

Ticagrelor_strand2019_PD_pru

The steady-state exposure-response curve of Åstrand M et al., British journal of clinical pharmacology 85(2):413–421 2019 (doi:10.1111/bcp.13812) — P2Y12 reaction units (PRU) against ticagrelor nmol l –1 — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.

The parameters, in the paper's terms

  E0    =        311          drug-free response (baseline) (PRU baseline ONSET/OFFSET, Q324)
  Emax  =       98.5 %        maximal effect term (E max, Q323)
  EC50  =        116 nmol l –1 exposure at half of the maximal effect term (EC 50, Q321)
  gamma =       1.59          Hill coefficient (Steepness of exposure‐response, Q325)

The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one nmol l –1 of ticagrelor per second of simulated time (exposure is in mol/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 311   (drug-free)
  exposure = EC50 (116 nmol l –1)  response 310.5
  exposure -> infinity  response 310

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realeffect (from SigmoidEmaxSweep)change from the drug-free baseline at that exposure

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Åstrand_2019: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate