modelMecamylamine_AlvarezJimenez2017_PD_adaptive_tracker
sigmoid_emax exposure-response sweep — Alvarez-Jimenez_2017 :: Adaptive tracker (Percentage of accuracy of the adaptive tracker test)
Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).
Information
Mecamylamine_AlvarezJimenez2017_PD_adaptive_tracker
The steady-state exposure-response curve of Alvarez-Jimenez R et al., Journal of psychopharmacology (Oxford, England) 31(2):192–203 2017 (doi:10.1177/0269881116681417) — Percentage of accuracy of the adaptive tracker test [%] against mecamylamine μg L -1 — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.
The parameters, in the paper's terms
E0 = 29 - drug-free response (baseline) (BL, Q324) Emax = 0.27 % maximal effect term (E max, Q323) EC50 = 97.2 μg L -1 exposure at half of the maximal effect term (EC 50, Q321) gamma = 1.58 Hill coefficient (γ, Q325)
The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one μg L -1 of mecamylamine per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).
What it reproduces
exposure = 0 response 29 (drug-free) exposure = EC50 (97.2 μg L -1) response 29 exposure -> infinity response 29
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | E0 (from PartialExposureResponseSweep) | 0 | response with no drug |
| Real | Emax (from PartialExposureResponseSweep) | 1 | maximal effect term — how it enters the response is set by the extending class |
| Real | EC50 (from PartialExposureResponseSweep) | 1 | exposure at half of the maximal EFFECT TERM (D50, for a dose sweep) |
| Real | gamma (from PartialExposureResponseSweep) | 1 | Hill coefficient |
| Real | exposure_per_s (from PartialExposureResponseSweep) | 1.0 | exposure units per second of simulated time — the sweep rate |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | exposure (from PartialExposureResponseSweep) | the driver being swept: a concentration, or a dose | |
| Real | frac (from PartialExposureResponseSweep) | Hill fraction, 0..1 — the shared part of every exposure-response shape | |
| Real | response (from PartialExposureResponseSweep) | modelled response at that exposure | |
| Real | effect (from SigmoidEmaxSweep) | change from the drug-free baseline at that exposure |
Revisions
- 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Alvarez-Jimenez_2017: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate