modelDoxycycline_Zhang2016_PD_kill_rate

sigmoid_emax exposure-response sweep — Zhang_2016 :: kill rate (kill rate)

Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).

Information

Doxycycline_Zhang2016_PD_kill_rate

The steady-state exposure-response curve of Zhang N et al., Frontiers in microbiology 7:653 2016 (doi:10.3389/fmicb.2016.00653) — kill rate [h−1] against doxycycline μg/mL — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.

The parameters, in the paper's terms

  E0    =        2.3 log10 CFU/mL drug-free response (baseline) (E0 (log10 CFU/mL), Q324)
  Emax  =       0.11 h−1      maximal effect term (Emax, Q323)
  EC50  =       0.32 μg/mL    exposure at half of the maximal effect term (EC50, Q321)
  gamma =       2.11          Hill coefficient (Hill’s slope, Q325)

The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one μg/mL of doxycycline per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 2.3   (drug-free)
  exposure = EC50 (0.32 μg/mL)  response 2.3
  exposure -> infinity  response 2.3

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realeffect (from SigmoidEmaxSweep)change from the drug-free baseline at that exposure

Revisions

  • 10/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Zhang_2016: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate