modelVoclosporin_Mayo2014_PD_cna
sigmoid_emax exposure-response sweep — Mayo_2014 :: CNa (calcineurin activity)
Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).
Information
Voclosporin_Mayo2014_PD_cna
The steady-state exposure-response curve of Mayo PR et al., Journal of clinical pharmacology 54(5):537–545 2014 (doi:10.1002/jcph.237) — calcineurin activity [pmol/min/mg] against voclosporin ng/mL — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.
The parameters, in the paper's terms
E0 = 1.15 pmol/min/mg drug-free response (baseline) (baseline immunosuppression, Q324) Emax = 0.87 pmol/min/mg maximal effect term (Maximum CNa Inhibition, Q323) EC50 = 123 ng/mL exposure at half of the maximal effect term (effective concentration, Q321) gamma = (library default) Hill coefficient
The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one ng/mL of voclosporin per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).
What it reproduces
exposure = 0 response 1.15 (drug-free) exposure = EC50 (123 ng/mL) response 0.715 exposure -> infinity response 0.28
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | E0 (from PartialExposureResponseSweep) | 0 | response with no drug |
| Real | Emax (from PartialExposureResponseSweep) | 1 | maximal effect term — how it enters the response is set by the extending class |
| Real | EC50 (from PartialExposureResponseSweep) | 1 | exposure at half of the maximal EFFECT TERM (D50, for a dose sweep) |
| Real | gamma (from PartialExposureResponseSweep) | 1 | Hill coefficient |
| Real | exposure_per_s (from PartialExposureResponseSweep) | 1.0 | exposure units per second of simulated time — the sweep rate |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | exposure (from PartialExposureResponseSweep) | the driver being swept: a concentration, or a dose | |
| Real | frac (from PartialExposureResponseSweep) | Hill fraction, 0..1 — the shared part of every exposure-response shape | |
| Real | response (from PartialExposureResponseSweep) | modelled response at that exposure | |
| Real | effect (from SigmoidEmaxSweep) | change from the drug-free baseline at that exposure |
Revisions
- 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Mayo_2014: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: accepted with caveats