modelEculizumab_Ter2023_PD_cp_activity

sigmoid_emax exposure-response sweep — Ter_2023 :: CP activity (classical pathway activity)

Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).

Information

Eculizumab_Ter2023_PD_cp_activity

The steady-state exposure-response curve of Ter Avest M et al., Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 38(2):362–371 2023 (doi:10.1093/ndt/gfac056) — classical pathway activity [%] against eculizumab mg/L — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.

The parameters, in the paper's terms

  E0    =      100.7 %        drug-free response (baseline) (Baseline CP activity, Q324)
  Emax  =       0.96 %        maximal effect term (Maximum inhibition, Q323)
  EC50  =         22 mg/L     exposure at half of the maximal effect term (Plasma IC50, Q322)
  gamma =       5.42          Hill coefficient (Hill coefficient, Q325)

The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one mg/L of eculizumab per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 1.007   (drug-free)
  exposure = EC50 (22 mg/L)  response 1.002
  exposure -> infinity  response 0.9974

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realeffect (from SigmoidEmaxSweep)change from the drug-free baseline at that exposure

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Ter_2023: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate