modelNaproxen_Bjrnsson2011_PD_pi

sigmoid_emax exposure-response sweep — Björnsson_2011 :: PI (pain intensity)

Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).

Information

Naproxen_Bjrnsson2011_PD_pi

The steady-state exposure-response curve of Björnsson MA et al., British journal of clinical pharmacology 71(6):899–906 2011 (doi:10.1111/j.1365-2125.2011.03924.x) — pain intensity [mm] against unbound naproxen mmol l -1 — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.

The parameters, in the paper's terms

  E0    =       52.7 mm       drug-free response (baseline) (PIbaseline, Q324)
  Emax  =          1 mm       maximal effect term (Emax, Q320)
  EC50  =      0.135 mmol l -1 exposure at half of the maximal effect term (EC50, Q321)
  gamma =       1.61          Hill coefficient (g, Q325)

The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one mmol l -1 of unbound naproxen per second of simulated time (exposure is in mol/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 52.7   (drug-free)
  exposure = EC50 (0.135 mmol l -1)  response 52.2
  exposure -> infinity  response 51.7

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realeffect (from SigmoidEmaxSweep)change from the drug-free baseline at that exposure

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Björnsson_2011: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate