modelNaproxen_Huntjens2006_PD_pge2

sigmoid_emax exposure-response sweep — Huntjens_2006 :: PGE2 (PGE2 inhibition (in vivo rat))

Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).

Information

Naproxen_Huntjens2006_PD_pge2

The steady-state exposure-response curve of Huntjens DR et al., British journal of pharmacology 148(4):396–404 2006 (doi:10.1038/sj.bjp.0706737) — PGE2 inhibition (in vivo rat) [ng ml-1] against naproxen ng ml-1 — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.

The parameters, in the paper's terms

  E0    =       65.9 ng ml-1  drug-free response (baseline) (I0, Q324)
  Emax  =       2.68 ng ml-1  maximal effect term (Imax y Intercept, Q323)
  EC50  =       2951 ng ml-1  exposure at half of the maximal effect term (IC50, Q322)
  gamma =       1.02          Hill coefficient (Hill coefficient, Q325)

The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one ng ml-1 of naproxen per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 6.59e-05   (drug-free)
  exposure = EC50 (2951 ng ml-1)  response 6.456e-05
  exposure -> infinity  response 6.322e-05

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realeffect (from SigmoidEmaxSweep)change from the drug-free baseline at that exposure

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Huntjens_2006: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate