The steady-state exposure-response curve of Zhou L et al., Frontiers in pharmacology 17:1760901 2026 (doi:10.3389/fphar.2026.1760901) — pain intensity against gabapentin ng/mL — obtained by sweeping the driver instead of simulating a dose. Model family: emax.

The parameters, in the paper's terms

  E0    =       7.31          drug-free response (baseline) (E0, Q324)
  Emax  =          1          maximal effect term (Imax, Q323)
  EC50  =     263.11 ng/mL    exposure at half of the maximal effect term (IC50, Q322)
  gamma = (library default) Hill coefficient

The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one ng/mL of gabapentin per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 7.31   (drug-free)
  exposure = EC50 (263.11 ng/mL)  response 6.81
  exposure -> infinity  response 6.31

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realeffect (from SigmoidEmaxSweep)change from the drug-free baseline at that exposure

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Zhou_2026: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: accepted with caveats