modelScopolamine_Ebert2001_PD_eeg_alpha_power

sigmoid_emax exposure-response sweep — Ebert_2001 :: EEG alpha power (total power in alpha frequency band)

Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).

Information

Scopolamine_Ebert2001_PD_eeg_alpha_power

The steady-state exposure-response curve of Ebert U et al., Journal of clinical pharmacology 41(1):51–60 2001 (doi:10.1177/00912700122009836) — total power in alpha frequency band [microV2] against scopolamine ng/ml — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.

The parameters, in the paper's terms

  E0    =       0.58 microV2  drug-free response (baseline) (E0, Q324)
  Emax  =       0.29 microV2  maximal effect term (Emax, Q323)
  EC50  =        0.6 ng/ml    exposure at half of the maximal effect term (EC50, Q321)
  gamma =       1.17          Hill coefficient (gamma, Q325)

The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one ng/ml of scopolamine per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 0.58   (drug-free)
  exposure = EC50 (0.6 ng/ml)  response 0.435
  exposure -> infinity  response 0.29

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realeffect (from SigmoidEmaxSweep)change from the drug-free baseline at that exposure

Revisions

  • 10/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Ebert_2001: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate