modelSalbutamol_Walsh2023_PD_pass
sigmoid_emax exposure-response sweep — Walsh_2023 :: PASS (Paediatric Asthma Severity Score (PASS))
Extends from Pharmacolibrary.Pharmacodynamic.SigmoidEmaxSweep (direct sigmoid Emax exposure-response curve, swept).
Information
Salbutamol_Walsh2023_PD_pass
The steady-state exposure-response curve of Walsh S et al., Archives of disease in childhood 108(4):316–322 2023 (doi:10.1136/archdischild-2022-324008) — Paediatric Asthma Severity Score (PASS) [fraction of PASS-score [0-9]] against salbutamol ng/ml — obtained by sweeping the driver instead of simulating a dose. Model family: sigmoid_emax.
The parameters, in the paper's terms
E0 = 0.381 fraction of PASS-score [0-9] drug-free response (baseline) (E0, Q324) Emax = 0.25 fraction of PASS-score [0-9] maximal effect term (EMAX, Q323) EC50 = 1.15 ng/ml exposure at half of the maximal effect term (EC50, Q321) gamma = 3.2 Hill coefficient (HILL, Q325)
The algebra is SigmoidEmaxSweep; this model only supplies the numbers. The x axis is one ng/ml of salbutamol per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).
What it reproduces
exposure = 0 response 0.381 (drug-free) exposure = EC50 (1.15 ng/ml) response 0.256 exposure -> infinity response 0.131
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | E0 (from PartialExposureResponseSweep) | 0 | response with no drug |
| Real | Emax (from PartialExposureResponseSweep) | 1 | maximal effect term — how it enters the response is set by the extending class |
| Real | EC50 (from PartialExposureResponseSweep) | 1 | exposure at half of the maximal EFFECT TERM (D50, for a dose sweep) |
| Real | gamma (from PartialExposureResponseSweep) | 1 | Hill coefficient |
| Real | exposure_per_s (from PartialExposureResponseSweep) | 1.0 | exposure units per second of simulated time — the sweep rate |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | exposure (from PartialExposureResponseSweep) | the driver being swept: a concentration, or a dose | |
| Real | frac (from PartialExposureResponseSweep) | Hill fraction, 0..1 — the shared part of every exposure-response shape | |
| Real | response (from PartialExposureResponseSweep) | modelled response at that exposure | |
| Real | effect (from SigmoidEmaxSweep) | change from the drug-free baseline at that exposure |
Revisions
- 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Walsh_2023: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate