recordModuleData

Data of PV module

Extends from Modelica.Icons.Record (Icon for records).

Information

This record defines parameters provided by photovoltaic module manufacturers.

Parameters

TypeNameDefaultDescription
StringmoduleName"Generic"
Modelica.Units.SI.VoltageVocCellRefVocRef/nsReference open circuit cell voltage > 0 at TRref
Modelica.Units.SI.VoltageVmpCellRefVmpRef/nsReference maximum power cell voltage > 0 at TRref
Integerns1Number of series connected cells
Integernb1Number of bypass diodes per module
Modelica.Units.SI.VoltageVtCellRefModelica.Constants.k*TRef/QReference temperature voltage of cell
Modelica.Units.SI.ChargeQ1.6021766208E-19Elementary charge of electron
Reference data
Modelica.Units.SI.TemperatureTRef298.15Reference temperature
Modelica.Units.SI.IrradianceirradianceRef1000Reference solar irradiance
Modelica.Units.SI.VoltageVocRef30.2Reference open circuit module voltage > 0 at TRref
Modelica.Units.SI.CurrentIscRef8.54Reference short circuit current > 0 at TRref and irradianceRef
Modelica.Units.SI.VoltageVmpRef24.0Reference maximum power module voltage > 0 at TRref
Modelica.Units.SI.CurrentImpRef7.71Reference maximum power current > 0 at TRref and irradianceRef
Modelica.Units.SI.LinearTemperatureCoefficientalphaIsc+0.00053Temperature coefficient of reference short circuit current at TRref
Modelica.Units.SI.LinearTemperatureCoefficientalphaVoc-0.00340Temperature coefficient of reference open circuit module voltage at TRref
Breakthrough data
Modelica.Units.SI.VoltageBvCell18Breakthrough cell voltage
Modelica.Units.SI.CurrentIbv1Breakthrough knee current
RealNbv0.74Breakthrough emission coefficient