modelTGM_Trina_Measurement_20160704

Measured irradiance model on 2016-07-04; Trina modules at TGM building in Vienna, Austria

Extends from Modelica.Icons.Example (Icon for runnable examples).

Information

This example uses measured irradiance data to supply the photovoltaic modules.

Parameters

TypeNameDefaultDescription
IntegernsModule8Number of series connected modules
IntegernpModule1Number of parallel connected modules
StringfileNameModelica.Utilities.Files.loadResource("modelica://PhotoVoltaics/Resources/WeatherData/TGM_Trina_20160704.txt")File name
StringcsvFileName"TGM_Trina_Measurement_20160704_power.csv"
PhotoVoltaics.Records.TSM_230_PC05moduleData

Components

TypeNameDefaultDescription
Modelica.Units.SI.IrradianceirradiancecombiTimeTable.y[1]Measured irradiance
Modelica.Units.SI.PowerpowerACcombiTimeTable.y[2]Measured AC power
Modelica.Units.SI.VoltageVACcombiTimeTable.y[3]Measured AC voltage
Modelica.Units.SI.CurrentIACcombiTimeTable.y[4]Measured AC current
Modelica.Units.SI.PowerpowerDCcombiTimeTable.y[5]Measured DC power
Modelica.Units.SI.VoltageVDCcombiTimeTable.y[6]Measured DC voltage
Modelica.Units.SI.CurrentIDCcombiTimeTable.y[7]Measured DC current
Modelica.Units.SI.TemperatureT1combiTimeTable.y[8]Temperature of ambient
Modelica.Units.SI.TemperatureT2combiTimeTable.y[9]Temperature of PV modules
PhotoVoltaics.Components.SimplePhotoVoltaics.SimplePlantSymmetricplant
Modelica.Electrical.Analog.Basic.Groundground
PhotoVoltaics.Components.Converters.QuasiStaticSinglePhaseConverterconverter
PhotoVoltaics.Components.Blocks.MPTrackerSamplempTracker
Modelica.Electrical.QuasiStatic.SinglePhase.Basic.GroundgroundAC
Modelica.Electrical.QuasiStatic.SinglePhase.Sources.VoltageSourcevoltageSource
Modelica.Electrical.Analog.Sensors.PowerSensorpowerSensor
Modelica.Blocks.Continuous.Integratorintegrator
Modelica.Blocks.Sources.CombiTimeTablecombiTimeTable
PhotoVoltaics_TGM.WriteCSVwriteCSV

Revisions