modelmyPartialLoad

Partial model for loads

Extends from Icons.myLoad (Icon for load node), Icons.myOnePortAC (Completing one port AC icon).

Information

This model is a common basis for constant and variable loads.

Parameters

TypeNameDefaultDescription
Types.myVoltageUNomReference voltage of the load
Types.myPerUnitlowVoltageif UNom <= 1000 then 0.9 else 0.95Lower percentage limit for acceptable voltage
Types.myPerUnithighVoltageif UNom <= 1000 then 1.1 else 1.05Higher percentage limit for acceptable voltage
Types.myVoltageminUlowVoltage*UNomMinimum acceptable value for U
Types.myVoltagemaxUhighVoltage*UNomMaximum acceptable value for U

Connectors

TypeNameDefaultDescription
Interfaces.myAcausalTerminalterminalTerminal of the node

Components

TypeNameDefaultDescription
Types.myCurrentICM.abs(terminal.i)Current flowing the load
Types.myVoltageUsqrt(3)*CM.abs(terminal.v)Voltage at the load
Types.myApparentPowerSsqrt(3)*I*UApparent power flowing the load