recordRXline

RX-line parameters, 1-phase

Extends from Common.Nominal.NominalDataAC (Units and nominal data AC).

Information

Relations.

  x = 2*pi*f_nom*L/R_base     reactance
  r = R / R_base              resistance

Coupling.

  positive coupled:     x0 > x
  uncoupled limit:      x0 = x

More info see package AC1ph_DC.Impedances.

Components

TypeNameDefaultDescription
BooleanpuUnits (from NominalData)true= true, if scaled with nom. values (pu), else scaled with 1 (SI)
SI.VoltageV_nom (from NominalData)1nominal Voltage (= base for pu)
SI.ApparentPowerS_nom (from NominalData)1nominal Power (= base for pu)
SI.Frequencyf_nom (from NominalDataAC)50nominal frequency
SIpu.Resistancer{0.1, 0.1}*1e-3resistance/km
SIpu.Reactance_kmx1e-3reactance/km
SIpu.Reactance_kmx03*xreactance/km zero-comp