modelTrafoIdeal

Ideal transformer, 1-phase

Extends from Partials.TrafoIdealBase (Base for ideal transformer, 1-phase).

Information

Ideal magnetic coupling, no stray-impedance, zero magnetisation current.

Parameters

TypeNameDefaultDescription
Datapar (from TrafoIdealBase)trafo parameter record
Initialization
Types.DynamicsdynType (from TrafoIdealBase)system.dynTypetransient or steady-state model
PS.Currenti1_start (from TrafoIdealBase)0start value of primary current
PS.Currenti2_start (from TrafoIdealBase)i1_startstart value of secondary current
Options
Booleanuse_tap_1_in (from TrafoIdealBase)false= true to enable input tap_1_in
Integertap_1 (from TrafoIdealBase)par.tap_neutral[1]fixed tap_1 position
Booleanuse_tap_2_in (from TrafoIdealBase)false= true to enable input tap_2_in
Integertap_2 (from TrafoIdealBase)par.tap_neutral[2]fixed tap_2 position
BooleandynTC (from TrafoIdealBase)falseenable dynamic tap-changing

Connectors

TypeNameDefaultDescription
Ports.TwoPin_pterm_p (from Port_p_n)positive terminal
Ports.TwoPin_nterm_n (from Port_p_n)negative terminal
Modelica.Blocks.Interfaces.IntegerInputtap_1_in (from TrafoIdealBase)1: index of voltage level
Modelica.Blocks.Interfaces.IntegerInputtap_2_in (from TrafoIdealBase)2: index of voltage level

Components

TypeNameDefaultDescription
PS.Voltagev1 (from PortTrafo_p_n)voltage 1
PS.Currenti1 (from PortTrafo_p_n)current 1
PS.Voltagev2 (from PortTrafo_p_n)voltage 2
PS.Currenti2 (from PortTrafo_p_n)current 2