modelPMgenerator

Generator inverter time-average

Extends from Partials.GenBase_ctrl (Generation base pm, synchronous machines).

Information

Generator with pm excitation and inverter for current-control. To be coupled to a mechanical engine. May contain a gear.

Note: for machines with gear w_start denotes the initial angular velocity at the generator-side!

Parameters

TypeNameDefaultDescription
Initialization
SI.AngularVelocityw_start (from GenBase_ctrl)0initial rpm (start-value if steady init)

Connectors

TypeNameDefaultDescription
Interfaces.ThermalV_nheat (from GenBase0)heat source port {stator, rotor}
Interfaces.Rotation_pflange (from GenBase_ctrl)
AC1ph_DC.Ports.TwoPin_nterm (from GenBase_ctrl)negative terminal
Modelica.Blocks.Interfaces.RealOutputi_meas (from GenBase_ctrl)measured current {i_d, i_q} pu
Modelica.Blocks.Interfaces.RealInputi_act (from GenBase_ctrl)actuated current {i_d, i_q} pu

Components

TypeNameDefaultDescription
Common.Thermal.HeatV_a_b_abheat_adapt (from GenBase_ctrl)
Geargear (from GenBase_ctrl)type of gear
Rotorrotor (from GenBase_ctrl)rotor generator
Generatorgeneratorsynchron pm generator
Inverterinverterinverter (average or modulated)

Contents

NameDescription
Generatorsynchron pm generator
Inverter