recordSynchron3rd_pm

Synchronous machine pm 3rd order parameters

Extends from Synchron3rd (Synchronous machine 3rd order parameters).

Information

Equivalent circuit on diagram layer!

The relation between 'flux induced by permanent magnet' Psi_pm [Wb] and 'magnetisation' psi_pm [pu] is given by the following relation;

  Psi_pm = psi_pm*V_nom/omega_nom
  psi_pm = Psi_pm*omega_nom/V_nom

Components

TypeNameDefaultDescription
BooleanpuUnits (from NominalData)true= true, if scaled with nom. values (pu), else scaled with 1 (SI)
SI.VoltageV_nom (from NominalData)1nominal Voltage (= base for pu)
SI.ApparentPowerS_nom (from NominalData)1nominal Power (= base for pu)
SI.Frequencyf_nom (from NominalDataAC)50nominal frequency
Booleanneu_iso (from Synchron3rd)isolated neutral if Y
Integerpp (from Synchron3rd)pole-pair number
Integerexcite (from Synchron3rd)excitation (1:el, 2:pm, 3:reluctance)
SIpu.MagneticFluxpsi_pm (from Synchron3rd)magnetisation (V/V_nom at open term at omega_nom)
SIpu.Reactancex_d (from Synchron3rd)syn reactance d-axis
SIpu.Reactancex_q (from Synchron3rd)syn reactance q-axis
SIpu.Reactancex_0 (from Synchron3rd)reactance 0-axis
SIpu.Resistancer_s (from Synchron3rd)resistance armature
SIpu.Resistancer_n (from Synchron3rd)resistance neutral to grd (if Y)