modelShuntBaseNonSym
Shunt base non symmetric, 3-phase dq0
Extends from ShuntBase (Shunt base, 3-phase dq0).
Information
Same as ShuntBase, but contains additionally a Park-transform which is needed for transformation of general impedance matrices from abc rest- to general dq0-system. (for example when coefficients of non symmetric systems are defined in abc representation.)
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Parameter Scaling | |||
| Boolean | puUnits (from Nominal) | true | = true, if scaled with nom. values (pu), else scaled with 1 (SI) |
| Nominal | |||
| SI.Voltage | V_nom (from Nominal) | 1 | nominal Voltage (= base for pu) |
| SI.ApparentPower | S_nom (from Nominal) | 1 | nominal Power (= base for pu) |
| SI.Frequency | f_nom (from NominalAC) | system.f_nom | nominal frequency |
| Initialization | |||
| Types.Dynamics | dynType (from ShuntBase) | system.dynType | transient or steady-state model |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Ports.ACdq0_p | term (from Port_p) | positive terminal |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| PS.Voltage | v (from ShuntBase) | ||
| PS.Current | i (from ShuntBase) |