recordTrafo3Ideal
Parameters for ideal 3-winding transformer, 3-phase
Extends from Common.Nominal.NominalDataTrafo (Units and nominal data transformer).
Information
Nominal voltage with 3 components: {prim, sec_a, sec_b}.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | puUnits (from NominalDataTrafo) | true | = true, if scaled with nom. values (pu), else scaled with 1 (SI) |
| SI.Voltage | V_nom (from NominalDataTrafo) | {1, 1} | {prim,sec} nom Voltage (= base of pu) |
| SI.ApparentPower | S_nom (from NominalDataTrafo) | 1 | nominal Power (= base of pu) |
| SI.Frequency | f_nom (from NominalDataTrafo) | 50 | nominal frequency |
| Integer | tap_neutral | {0, 0, 0} | {1,2a,2b}: neutral tap position |
| SIpu.Voltage | dv_tap | {0, 0, 0} | {1,2a,2b}: delta-v per tap change |
| SIpu.Resistance | r_n | {1, 1, 1} | {1,2a,2b}: resistance neutral to grd (if Y) |