.PowerSystems.Examples.AC3ph.Precalculation.Z_matrixTrDat1

Information

Equivalent circuit on diagram layer!

Test generator, transient order = 1.

Transient data are:

  tc_d  = {0.684058354104098} d-axis
  to_d  = {4.171788659833010} d-axis
  xtr_d = {0.290231213872833} d-axis

  tc_q  = {0.684058354104098} q-axis
  to_q  = {4.171788659833010} q-axis
  xtr_q = {0.290231213872833} q-axis

Corresponding circuit data are:

  {r[1:n], r_0} = {0.0011, 0.005},    d- and q-axis
  {xsig[1:n], xsig_0} = {0.13, 0.17}, d- and q-axis
  {xm[1:n], xm_0} = {0, 1.6} d- and q-axis (no coupling terms in transient order 1)
  v_f denotes the field voltage.

The code uses

  xsig_s for xsig_0: armature leakage reactance
  xsig_r for xsig:   rotor leakage reactances
  r_s    for r_0:    armature (stator) resistance
  r_r    for r:      rotor resistances

up users guide


Generated at 2024-12-21T19:25:56Z by OpenModelicaOpenModelica 1.24.3 using GenerateDoc.mos