modelFixedSpeedTG
Fixed speed turbo-generator rotor
Information
Turbine-rotor and generator-rotor together represent one single rotating object without dynamical properties. The constant rotor velocity is determined at initialisation.
No pole pair reduction of equations of motion is performed.
Therefore phi and w represent the mechanical angle and angular velocity.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Initialization | |||
| Types.Dynamics | dynType | system.dynType | transient or steady-state model |
| SI.AngularVelocity | w_start | 0 | initial rotor angular velocity |
| Nominal | |||
| SI.AngularVelocity | w_nom | 1 | nominal angular velocity |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Interfaces.Rotation_n | airgap | to airgap electric machine | |
| Modelica.Blocks.Interfaces.RealInput | power | turbine power pu | |
| Modelica.Blocks.Interfaces.RealOutput | speed | turbine speed pu |