modelDutyCycleAb
An abstract model with a common circuit for all
implementations of a duty cycle controller.
Derived models must provide additional pins and
additional building blocks that handle either the
reference voltage or duty cycle directly.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Voltage | Vm | 2 | Amplitude voltage of the internal sawtooth voltage generator [V] |
| SI.Voltage | Von | 2 | Output on-voltage [V] |
| SI.Frequency | fs | 100.e+3 | Switching frequency of the modulator [Hz] |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| EL.Interfaces.PositivePin | p | Positive output pin | |
| EL.Interfaces.NegativePin | n | Negative output pin |