modelTwoGeneratorsConstantLoad

One generator with constant load at equilibrium

Extends from Models.PowerSystem.

Information

Test case with a two generator connected by a transmission line. Each generator has a local balanced load of 1 p.u. The model is at equilibrium, with zero power transfer along the line.

Parameters

TypeNameDefaultDescription
IntegerN (from PowerSystem)1Number of generators in the network
IntegerM (from PowerSystem)4Number of volumes in the superheater models
PowerP_nom (from PowerSystem)500e6Nominal power of a single generator
Frequencyf_ref (from PowerSystem)50Reference network frequency
AngularVelocityomega_ref (from PowerSystem)2*pi*f_ref
SI.TimeT_sfc (from PowerSystem)20Time constant of secondary frequency control
RealP_d (from PowerSystem)0.5*P_nom/omega_refPower dissipation coefficient
Realdroop (from PowerSystem)0.10Average network droop
Realpi (from PowerSystem)Modelica.Constants.pi

Components

TypeNameDefaultDescription
Frequencyf (from PowerSystem)Network frequency measured at node 1 for secondary frequency control
Power[N]P_load (from PowerSystem)ones(N)*P_nomActive power consumed by loads - replace the default binding
Power[N,N]P_ex (from PowerSystem)Power going from generator i to generator j
Power[N,N]P_diss (from PowerSystem)Power dissipated by the generators i and j
Power[N]P_a (from PowerSystem)Net active power out of generator i
PowerP_f (from PowerSystem)P_nomPower factor of a single trunk of transmission line
PowerP_sfc (from PowerSystem)Additional power request for secondary frequency control
Generator[N]generator (from PowerSystem)