modelWall

Cylindrical metal tube with variable number of wall layers Nwall

Information

This model is based on the Walllayer model which represents a cylindrical metal tube wall with a single layer. The parameter numberOfWallLayers says how many layers will be accounted for in that wall. The counting of layers begins at the inner side, i.e. layer[numberOfNodes] is the outside layer.

Author: Haiko Steuer SCD
Checked by:
Protection class: internal

License, Copyright and Disclaimer


Licensed by Siemens AG under the Siemens Modelica License 2

Copyright 2007-2012 Siemens AG. All rights reserved.

This Modelica package is free software and the use is completely at your own risk; it can be redistributed and/or modified under the terms of the Siemens Modelica License 2. For license conditions (including the disclaimer of warranty) see Siemens Modelica License 2 .

Parameters

TypeNameDefaultDescription
IntegernumberOfNodes2Number of nodes
IntegernumberOfWallLayers3Number of wall layers
IntegernumberOfParallelTubes1Number of parallel tubes
SI.Lengthlength1Tube length
SI.LengthdiameterInner0.08Internal diameter (single tube)
SI.LengthwallThickness0.008Wall thickness
SI.Temperature[numberOfNodes]T_startfill(300, numberOfNodes)Temperature start values for inner layer
Material
SiemensPower.Utilities.Structures.PropertiesMetalmetalWall metal properties

Connectors

TypeNameDefaultDescription
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_aport_extOuter heat port
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_bport_intInner heat port

Components

TypeNameDefaultDescription
SiemensPower.Components.SolidComponents.Walllayer[numberOfWallLayers]layer

Revisions

  • December 2006 by Haiko Steuer