modelForcedCommSwitch

Forced commuting switch, 3-phase dqo

Extends from Base.Units.NominalVI (Nominal values).

Information

Switching by forced change of current-voltage ratio.

Does not allow single-phase switching. This model acts directly on the current vector in the chosen reference frame and avoids any transformation of variables. To be used, if details of the switching process are not of interest.

'closed' and 'open' determine the mechanical switch-position.
Electrically the switch is on, if it is 'closed', whereas the currents start decreasing exponentially, when it is opened.

A single scalar control-input is sufficient.

The transition between the 'off' conductivity (epsG) and the 'on' resistivity (epsR) is continuous with an exponential relaxation function

  f = (exp(-dt^p/2) - exp(-1/2))/(1 - exp(-1/2))
with
  dt          relative time measured from switching instant
  t_relax     relaxation time
  p           power of exponent

Parameters

TypeNameDefaultDescription
Realeps{1e-4, 1e-4}{resistance 'closed', conductance 'open'}
SI.Timet_relax10e-3switch relaxation time
Integerp_relax4power of relaxation exponent
Nominal
SI.VoltageV_nom (from NominalVI)1nom Voltage
SI.CurrentI_nom (from NominalVI)1nom Current

Connectors

TypeNameDefaultDescription
Base.Interfaces.ACdqo_pterm_ppositive terminal
Base.Interfaces.ACdqo_nterm_ntnegative terminal 'true'
Base.Interfaces.ACdqo_nterm_nfnegative terminal 'false'
Modelica.Blocks.Interfaces.BooleanInputcontroltrue: p - nt closed, false: p - nf closed

Components

TypeNameDefaultDescription
SI.Voltagev_t
SI.Voltagev_f
SI.Currenti_t
SI.Currenti_f

Contents

NameDescription
relaxationprotected