modelFault_abc
a to b to c fault, 3-phase dqo
Extends from Partials.FaultBase (Line fault base, 3-phase dqo).
Information
Connect to 'fault'-terminal of faulted line.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Time | t_on (from FaultBase) | 0.1 | approx time fault on |
| SIpu.Angle_deg | phi_on (from FaultBase) | 0 | voltage phase angle fault on |
| Integer | n_phRef (from FaultBase) | 1 | of reference phase |
| SI.Resistance | epsR (from FaultBase) | 1e-4 | resistance 'fault' |
| SI.Conductance | epsG (from FaultBase) | 1e-4 | conductance 'no fault' |
| Integer | n_ph | 1 | double connected phase, 2=(1-2,2-3) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Base.Interfaces.ACdqo_p | term (from Port_f) | fault terminal |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Voltage | v (from FaultBase) | voltage | |
| SI.Current | i (from FaultBase) | current | |
| SI.Voltage | v_abc (from FaultBase) | voltage phase a, b, c | |
| SI.Current | i_abc (from FaultBase) | current phase a, b, c | |
| Common.Switching.Short | fault_pp1 | fault model | |
| Common.Switching.Short | fault_pp2 | fault model |