recordTrafoStray

Parameters for ideal magnetic coupling transformer, 3-phase

Extends from TrafoIdeal (Parameters for ideal transformer, 3-phase).

Information

Parameters

TypeNameDefaultDescription
SIpu.Resistancer_n1 (from TrafoIdeal)11: resistance neutral to grd (if Y)
SIpu.Resistancer_n2 (from TrafoIdeal)12: resistance neutral to grd (if Y)
SIpu.Resistancer{0.05, 0.05}{1,2}: resistance
SIpu.Reactancex{0.05, 0.05}{1,2}: stray reactance
SIpu.Reactancex0{x[1], x[2]}{1,2}: stray reactance zero-comp
Options
SIpu.Voltagev_tc1 (from TrafoIdeal)fill(1, 0)1: v-levels tap-changer
SIpu.Voltagev_tc2 (from TrafoIdeal)fill(1, 0)2: v-levels tap-changer
Nominal
Base.Types.Unitsunits (from NominalDataTrafo)Types.puSI | pu
SI.VoltageV_nom (from NominalDataTrafo){1, 1}{prim,sec} nom Voltage (= base if pu)
SI.ApparentPowerS_nom (from NominalDataTrafo)1nom Power (= base if pu)
SI.Frequencyf_nom (from NominalDataTrafo)system.f_nomnom frequency