modelTrafoIdeal

Ideal transformer, 3-phase dqo

Extends from Partials.TrafoIdealBase (Base for ideal transformer, 3-phase dqo).

Information

Ideal magnetic coupling, no stray-impedance, zero magnetisation current.

Parameters

TypeNameDefaultDescription
BooleanD_Dfalseset true if Delta-Delta topology!
BooleanstIni_en (from TrafoIdealBase)trueenable steady-state initial equation
BooleandynTC (from TrafoIdealBase)falseenable dynamic tap-changing
Parameters.TrafoIdealpar (from TrafoIdealBase)trafo parameter

Connectors

TypeNameDefaultDescription
Base.Interfaces.ACdqo_pterm_p (from Port_p_n)positive terminal
Base.Interfaces.ACdqo_nterm_n (from Port_p_n)negative terminal
Modelica.Blocks.Interfaces.IntegerInputtap_p (from TrafoIdealBase)1: index of voltage level
Modelica.Blocks.Interfaces.IntegerInputtap_n (from TrafoIdealBase)2: index of voltage level

Components

TypeNameDefaultDescription
Topology.Ytop_p (from YDportTrafo_p_n)p: Y or Delta topology
Topology.Ytop_n (from YDportTrafo_p_n)n: Y or Delta topology
SI.Voltagev1 (from YDportTrafo_p_n)top_p.v_cond/w1voltage conductor
SI.Currenti1 (from YDportTrafo_p_n)top_p.i_cond*w1current conductor
SI.Voltagev_n1 (from YDportTrafo_p_n)top_p.v_nvoltage neutral
SI.Currenti_n1 (from YDportTrafo_p_n)top_p.i_ncurrent neutral to ground
SI.Voltagev2 (from YDportTrafo_p_n)top_n.v_cond/w2voltage conductor
SI.Currenti2 (from YDportTrafo_p_n)top_n.i_cond*w2current conductor
SI.Voltagev_n2 (from YDportTrafo_p_n)top_n.v_nvoltage neutral
SI.Currenti_n2 (from YDportTrafo_p_n)top_n.i_ncurrent neutral to ground