modelFixedSpeedTG

Fixed speed turbo-generator rotor

Information

Turbine-rotor and generator-rotor together represent one single rotating object without dynamical properties. The constant rotor velocity is determined at initialisation.

No pole pair reduction of equations of motion is performed.
Therefore phi and w represent the mechanical angle and angular velocity.

Parameters

TypeNameDefaultDescription
SI.AngularVelocityw_ini0initial rotor angular velocity
SI.AngularVelocityw_nom1nom ang velocity

Connectors

TypeNameDefaultDescription
Base.Interfaces.Rotation_nairgapto airgap electric machine
Modelica.Blocks.Interfaces.RealInputpowerturbine power pu
Modelica.Blocks.Interfaces.RealOutputspeedturbine speed pu