recordAsynchron400V_30kVA

Asynchronous machine, example

Extends from Spot.Base.Icons.Record (Record icon).

Information

Parameters

TypeNameDefaultDescription
Booleanneu_isofalseisolated neutral if Y
Integerpp8pole-pair number
SIpu.Reactancex3total reactance d- and q-axis
SIpu.Reactancex_o0.1reactance o-axis
SIpu.Resistancer_s0.04resistance stator
SIpu.Resistancer_n1resistance neutral to grd (if Y)
BooleantransDattrueuse transient data
Booleanuse_xtrtrueuse t_closed and x_transient?
SIpu.Reactancextr{0.196667}transient reactance {xtr', xtr'', ..}
SI.Timetc{0.0130419}time constant closed-loop {tc', tc'', ..}
SI.Timeto{0.198944}time constant open-loop {to', to'', ..}
SIpu.Reactancexsig_s0.1leakage reactance stator
SIpu.Reactancexsig_r{0.1}leakage reactance rotor
SIpu.Resistancer_r{0.04}resistance rotor
StringunitsSpot.Base.Types.puSI | pu
SI.VoltageV_nom400nom Voltage (= base if pu)
SI.ApparentPowerS_nom30e3nom Power (= base if pu)
SI.Frequencyf_nom50nom frequency