recordSynchron20kV_1200MVA

Synchronous machine, example

Extends from Spot.Base.Icons.Record (Record icon).

Information

Parameters

TypeNameDefaultDescription
Booleanneu_isofalseisolated neutral if Y
Integerpp1pole-pair number
Integerexcite1excitation (1:electric)
SIpu.MagneticFluxpsi_pm0magnetisation (V/V_nom at open term at omega_nom)
SIpu.Reactancex_d2.29syn reactance d-axis
SIpu.Reactancex_q1.95syn reactance q-axis
SIpu.Reactancex_o0.1reactance o-axis
SIpu.Resistancer_s0.004resistance armature
SIpu.Resistancer_n1resistance neutral to grd (if Y)
BooleantransDattrueuse transient data
Booleanuse_xtrtrueuse x_transient and t_closed?
SIpu.Reactancextr_d{0.361123, 0.283696}trans reactance d-axis {xtr_d', xtr_d'', ..}
SIpu.Reactancextr_q{0.464817, 0.303593}trans reactance q-axis {xtr_q', xtr_q'', ..}
SI.Timetc_d{0.93133, 0.0253919}time constant closed-loop d-axis {tc_d', tc_d'', ..}
SI.Timetc_q{0.270197, 0.041458}time constant closed-loop q-axis {tc_q', tc_q'', ..}
SI.Timeto_d{5.94309, 0.0321197}time constant open-loop d-axis {to_d', to_d'', ..}
SI.Timeto_q{1.207780, 0.0595723}time constant open-loop q-axis {to_q', to_q'', ..}
Booleanuse_if0trueinduced field current and phase available?
SIpu.Currentif00.286induced field current at v_s=Vnom/0deg
SIpu.Angle_degif0_deg-56angle(if0) at v_s=Vnom/0deg (sign: i_f behind v_s)
Realtol1e-6tolerance precalculation
SIpu.Reactancexsig_s0.2leakage reactance armature
SIpu.Reactancexsig_rd{0.1294, 0.03498}leakage reactance rotor d-axis {f, D, ..}
SIpu.Reactancexsig_rq{0.3948, 0.1527}leakage reactance rotor q-axis {Q1, ..}
SIpu.Reactancexm_d{0.05965}coupling-reactance d-axis {xm1, ..}
SIpu.Resistancer_rd{1.321e-3, 14.38e-3}resistance rotor d-axis {f, D, ..}
SIpu.Resistancer_rq{7.037e-3, 20.38e-3}resistance rotor q-axis {Q1, ..}
StringunitsSpot.Base.Types.puSI | pu
SI.VoltageV_nom20e3nom Voltage (= base if pu)
SI.ApparentPowerS_nom1200e6nom Power (= base if pu)
SI.Frequencyf_nom50nom frequency
SI.CurrentIf_nom8000nom field current (V=V_nom at open term)