modelTreeWinding
Tree winding transformer
Information
Primary and secondary signals show a topology dependent phase shift.
Y-Y and Delta-Delta configuration:
no phase shift.
Y-Delta configuration:
shift secondary vs primary voltage is -30deg.
Delta_Y configuration:
shift secondary vs primary voltage is +30deg.
Compare:
meter12.alpha_v voltage phase secondary Y-Y topology meter22.alpha_v voltage phase secondary Y_Delta topology
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Spot.System | system | ||
| Spot.ACdqo.Sources.Voltage | voltage | ||
| Spot.ACdqo.Sensors.PVImeter | meter1 | ||
| Spot.ACdqo.Nodes.BusBar | bus | ||
| Spot.ACdqo.Transformers.Trafo3Stray | trafo3Stray | ||
| Spot.ACdqo.Sensors.PVImeter | meter12 | ||
| Spot.ACdqo.ImpedancesYD.Resistor | res12 | ||
| Spot.ACdqo.Sensors.PVImeter | meter22 | ||
| Spot.ACdqo.ImpedancesYD.Resistor | res22 | ||
| Spot.ACdqo.Nodes.GroundOne | grd |