.TAeZoSysPro.FluidDynamics.BasesClasses.Interface_liq_gas

Information

Interface_liq_gas

This components allows to model a flat interface between a liquid and surrounding gas where evapo-condensation, boiling, radiation and convection occur. This component is designed to work with moist air media.

Evapo-condensation

The mathematical model of evapo-condensation uses the same approach than in the Condensation module. It assumed that the limiting phenomenon for the transfer is the ability to bring the mass of moist air into contact to a wall.

Convection

Regarding the convection, the approach is the same than for the FreeConvection module of the HeatTransfer package. The correlation used is ground_ASHRAE.

Radiation

The radiative heat transfer is computed using the CarrollRadiation module.

Boiling

The boiling is modelled by an homogeneneous formation of bubbles of equal diameter (no coalescence, no growth, no collapse) that would be formed in the liquid node and that escape by the interface.
The bubble formation rate is deduced from the fraction of gas itself deduced from the liquid node specific enthalpy, the bubble and dew specific enthalpy:

The diameter of bubble is computed from the amount of gas, from an arbitrary number density of bubble (number of bubble per cubic meter of liquid) and from the knowledge of the state of the liquid node connected to the interface. By default n_bubbles = 150e6 m-3

The velocity of bubbles is computed from the steady balance between the buoyancy force and the friction force. The weight of the bubble in neglected and the density term of liquid phase regarding the density of the gas phase in neglected in the buoyancy force claculation. The flow regime considered for the friction is laminar and the bubbles are assimilated to spheres.

The boiling mass flow rate derives from the surface aera of the interface corrected by the ratio between the volume of bubbles and the total volume of the liquid node connected to the interface module.

Where:

Port heat and mass flows

The heat exchanged from radiation, convection, evapo-condensation and boiling is transfered via the heatPort_a. The fluidPort_a is just used to transfer mass from the liquid to the atmosphere for evaporation and the vice versa for condensation. It is not used to transport energy.