modelRankineCycle
Extends from TRANSFORM.Icons.Example (Icon for runnable examples).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.MassFlowRate | m_flow | 100 | Flow rate in cycle |
| SI.Pressure | p_steam | 8.6e6 | Steam pressure |
| SI.Temperature | T_steam | SI.Conversions.from_degC(500) | Steam temperature |
| SI.Pressure | p_condenser | 1e4 | Condenser pressure |
| SI.PressureDifference | dp_pump | p_steam - p_condenser |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Mechanics.Rotational.Sensors.PowerSensor | powerSensor | ||
| Electrical.Sources.FrequencySource | boundary | ||
| Modelica.Thermal.HeatTransfer.Sources.FixedTemperature | Thot_setPoint | ||
| System | system | ||
| Machines.SteamTurbine | steamTurbine | ||
| Volumes.IdealCondenser | condenser | ||
| Modelica.Fluid.Vessels.ClosedVolume | boiler | ||
| Machines.Pump | pump | ||
| Electrical.PowerConverters.Generator | generator | ||
| TRANSFORM.Fluid.Sensors.SpecificEnthalpy | specificEnthalpy_out | ||
| TRANSFORM.Fluid.Sensors.SpecificEnthalpy | specificEnthalpy_in | ||
| TRANSFORM.Fluid.Sensors.MassFlowRate | massFlowRate | ||
| SI.Power | Q_totalTh | Total thermal power | |
| SI.Efficiency | eta_overall | Overall Rankine efficiency | |
| Utilities.ErrorAnalysis.UnitTests | unitTests |
Contents
| Name | Description |
|---|---|
| Working fluid |