modelPartialRankine
Rankine cycle model
Information
Description
Example of a steam cycle configuration with reheat, two pre-heaters and one dearator.
Parameters
| Type | Name | Default | Description |
| Integer | nbr_pumps_LP | 3 | Number of low pressure feed-water pumps |
| Integer | nbr_pumps_HP | 3 | Number of high pressure feed-water pumps |
| Real | eta_is_HPT | 0.84 | Turbine isentropic efficiency |
| Real | eta_is_LPT | 0.85 | Turbine isentropic efficiency |
| Real | eta_mech | 0.99 | Turbine mechanical efficiency |
| Nominal operating data |
| Records.RankineNominalValues | nominalData | | Nominal data |
| Initialization |
| Records.RankineStartValues | initData | | Initialization data |
Contents
| Name | Description |
Medium | |