modelConstAlpha
constant alpha at column outside wall
Extends from ThermalSeparation.Wall.BaseWall (Model of the heat loss at the column outer wall).
Information
for information see BaseWallParameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | n (from BaseWall) | ||
| Boolean | stat (from BaseWall) | false | true if wall is calculated stationary |
| SI.Temperature | T_start (from BaseWall) | initial temperature of the wall | |
| SI.SurfaceCoefficientOfHeatTransfer | alpha_inner (from BaseWall) | 200 | heat transfer coefficient at inner side of the wall |
| SI.SurfaceCoefficientOfHeatTransfer | alpha_const | 200 | Heat transfer coefficient at the surface of the outer wall of the column |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Temperature | T_amb (from BaseWall) | ||
| Geometry | geometry (from BaseWall) | Geometry Record of the corresponding section | |
| SI.Temperature[n] | T_wall (from BaseWall) | wall temperature | |
| SI.Temperature[n] | T (from BaseWall) | ||
| SI.HeatFlowRate[n] | Qdot (from BaseWall) | heat flow from inner side of the wall to the wall | |
| SI.HeatFlowRate[n] | Qdot_out (from BaseWall) | heat flow from the wall to the outer side of the wall |