modelCondPlant_cc

Condensation plant with condenser ratio control (type ImpPressureCondenser_tap)

Extends from Interfaces.CondPlant_base (Base class for Condensation Plant (simplified version)).

Parameters

TypeNameDefaultDescription
SI.Pressurep (from CondPlant_base)Pressure of condesation
SI.VolumeVtot (from CondPlant_base)Total volume condensing fluid side
RealsetPoint_ratioSetPoint ratio Steam Volume / Total Volume
Initialization
SI.VolumeVlstart (from CondPlant_base)Start value of the liquid volume
BooleanSSInit (from CondPlant_base)falseSteady-state initialization

Connectors

TypeNameDefaultDescription
Water.FlangeASteamIn (from CondPlant_base)
Water.FlangeBWaterOut (from CondPlant_base)
Buses.SensorsSensorsBus (from CondPlant_base)
Buses.ActuatorsActuatorsBus (from CondPlant_base)

Components

TypeNameDefaultDescription
Control.PIDpID
Modelica.Blocks.Sources.ConstantsetPoint
Components.CondenserPreP_tapcondenserIdeal_tap
Water.SourceMassFlowsourceTap
ThermoPower.PowerPlants.SteamTurbineGroup.Components.Comp_bubble_hBubbleEnthalpy